The requirements to carrying out GDV-diagnostics

  • The room should be well ventilated. There shouldn’t be anyone in the room except the patient and the researcher. During GDV-diagnostics the patient should be relaxed and shouldn’t speak.
  • Before GDV-diagnostics damp hands should be dried with a dry cloth. Long nails should be cut short.
  • All metal objects (such as rings, bracelets, watch) should be removed from the patient’s hands.
  • A finger is positioned in the center of GDV-device so that the image shouldn’t move beyond the window frame (angle of slope is 10 – 30), and the finger should be perpendicular to the GDV-device front wall.

Requirements to the computer for GDV-diagnostics

Minimum:
Pentium-200MHz and higher
RAM – 32 Mb
100 Mb free space on the hard disk
SVGA display with resolution not less than 800 x 600 and 16 bit colours
Videocard with 2 Mb memory
USB-port
Operation system – Windows 98, ME, 2000.

Optimum: 400 MHz, 64 Mb RAM, 500 Mb free space on the hard disk.

GDV-diagnostics results

Organism state assessment by GDV-method is carried out on the basis of the analysis of the obtained GDV-images, processed with the help of standard programs package. The medical decision on the basis of the research study is made by a doctor.

After the procedure the following images and data can be printed:

1. GDV-images of fingertips with sector analysis and problematic zones determination, GDV-images digital characteristics (“GDV Screening“).

2. Diagrams of the energy state of the human main systems and organs (“GDV Diagram“) – norm, hypo- and hyper-function.

увеличить

3. GDV-glow distribution around human body (“GDV Energy Fields“)

увеличить

Patients examination results are saved into computer memory, floppy disks, CDs and other memory drives. It’s possible to compare them both during treatment and during follow-up. The created data bases might be used both in practical activity and scientific research.

The technique of carrying out GDV-diagnostics of the patient

1. GDV capture (shooting) of 10 fingertips (GDV-grams)

GDV Capture” program is used for registration of GDV glow and saving of GDV-grams files and GDV video to a computer disk.

GDV Capture” program functions in two modes – for static (frame-by frame) and dynamic (video) recording. It enables one to quickly and easily carry out the recording of 10 fingertips, up to 100 GDV-grams of liquids and other biological objects, as well as the recording of short video-films of a gas discharge (GDV-video).

увеличить

2. Carrying out GDV-grams computer analysis.

Computer analysis implies sector diagnostics and parametric analysis of GDV-grams.

Sector diagnostics is based on the diagnostic table, relating the characteristics of fingers’ separate zones glow to the functional state of the organism’s different systems and organs. On the basis of GDV-grams a model of the biological field distribution around human body is built.

Parametric analysis is based on more than 30 parameters of GDV-grams, as well as on the factor and correlation analysis. Geometry, brightness, structure, fractality, probability and other parameters are studied.